管系環(huán)焊縫射線檢測透照次數(shù)計(jì)算

  • 打印
  • 收藏
收藏成功


打開文本圖片集

摘    要:本文討論了ASME V和CB/T3558兩個(gè)標(biāo)準(zhǔn)的相關(guān)條款,并根據(jù)工件規(guī)格及X射線機(jī)曝光曲線,計(jì)算出管系環(huán)向?qū)雍缚p符合ASME V標(biāo)準(zhǔn)要求的一次透照長度,為現(xiàn)場實(shí)際操作提供參考,提高射線檢測工作效率。

關(guān)鍵詞:黑度范圍;有效長度;環(huán)縫檢測

中圖分類號:U671.8                                  文獻(xiàn)標(biāo)識碼:A

Calculation of Penetrate Times for Piping

Weld Radiographic Testing

GUO Dazhou,  ZHANG Biao,  DONG Xue,  PENG Lvgao,  XU Wentao

( CSSC Huangpu Wenchong Shipbuilding Co., LTD., Guangzhou 511462 )

Abstract: This paper discusses about the relevant clauses of ASME V and CB/T3558, and use workpiece specifications and X-ray exposure curve to calculate the effective length of circumferential butt weld in accordance with ASME V standard. This parameter can provide reference for the actual operation. The calculation of the maximum effective length can improve the efficiency of X-ray detection.

Key words: film density range; effective length; circumferential weld test

1     前言

我司承建的某海洋石油鉆井平臺,沖樁管系有大量的環(huán)向?qū)咏宇^環(huán)焊縫需要進(jìn)行100%射線照相檢測。(剩余5540字)