負(fù)極搭鐵線拆除不當(dāng)引起的蓄電池虧電故障分析

  • 打印
  • 收藏
收藏成功


打開(kāi)文本圖片集

【摘  要】本文通過(guò)一起因負(fù)極搭鐵線拆除不當(dāng)導(dǎo)致蓄電池虧電故障的排除案例,對(duì)由兩塊蓄電池組合給功率較小的底盤(pán)發(fā)動(dòng)機(jī)和功率較大的特裝發(fā)動(dòng)機(jī)同時(shí)供電的電路進(jìn)行分析,提出正確斷開(kāi)搭鐵線的方法。

【關(guān)鍵詞】蓄電池;搭鐵;虧電

中圖分類號(hào):U463.6    文獻(xiàn)標(biāo)志碼:B    文章編號(hào):1003-8639( 2022 )08-0103-02

Analysis of Battery Power Loss Caused by Improper Removal of Negative Grounding Wire

ZOU Kai-feng,YAO Ben-jun

(Naval Aeronautical University Qingdao Campus,Qingdao 266041,China)

【Abstract】Through the elimination of a battery power loss fault caused by improper removal of the negative grounding wire,this paper analyzes the circuit that the combination of two batteries supplies power to the chassis engine with small power and the special engine with large power at the same time,and puts forward the correct method of disconnecting the grounding wire.

【Key words】battery;grounding;power loss

作者簡(jiǎn)介

鄒開(kāi)鳳(1968—),男,副教授,碩士,研究方向?yàn)楹娇账恼狙b備保障。(剩余2579字)