注射泵質量控制標準與檢測方法分析

打開文本圖片集
【摘要】本文首先分析了注射泵校準的質量控制標準及注射泵檢測時的影響因素,其次基于方差分析方法研究了注射泵檢測時的誤差來源,并使用某醫(yī)院設備進行實例研究。結果表明,本研究所采用的檢測方法能夠有效地提高注射泵的整體質量控制水平,滿足臨床應用。
【關鍵詞】注射泵;質量控制;檢測
【DOI編碼】10.3969/j.issn.1674-4977.2024.06.038
Analysis of Quality Control Standards and Testing Methods for Injection Pump
WANG Lin
(Guangdong Heyuan Supervision Testing Institute of QualityAnd Metrology, Heyuan 517000, China)
Abstract: This paper first analyzes the quality control standards for injection pump calibration and the influencing factors in the detection of syringe infusion pumps. Secondly, based on the variance analysis method, it studies the error sources in the detection of injection pumps and conducts a case study using equipment from a hospital. The results show that the detection method used in this study can effectively improve the overall quality control level of injection pumps and meet clinical applications.
Keywords: injection pumps; quality control; test
1注射泵檢測及影響因素分析
注射泵主要由電機、控制系統(tǒng)、輸液管路和注射泵頭等部件組成。(剩余4176字)