【摘要】文章依據(jù)JJG 692—2010《無(wú)創(chuàng)自動(dòng)測(cè)量血壓計(jì)檢定規(guī)程》并結(jié)合工作經(jīng)驗(yàn),分析了電子血壓計(jì)的外觀、靜態(tài)壓力、示值重復(fù)性等檢定項(xiàng)目,重點(diǎn)討論了靜態(tài)壓力的測(cè)量方法,并對(duì)其結(jié)果進(jìn)行了不確定度評(píng)定。
【關(guān)鍵詞】電子血壓計(jì);靜態(tài)壓力;不確定評(píng)定
【DOI編碼】10.3969/j.issn.1674-4977.2024.01.069
Analysis and Discussion on Metrological Verification Items of Non-invasive Automatic Measurement Electronic Sphygmomanometer
CHEN Shurong
(Beijing Xicheng Institute of Metrology, Beijing 100055, China)
Abstract: Based on JJG 692—2010 Non-invasive Automated Sphygmomanometers and daily work experience, the article analyzes the verification items of electronic blood pressure meters, such as appearance, static pressure, and repeatability of indication. The focus is on discussing the measurement method of static pressure, and evaluating the uncertainty of the results.
Keywords: digital electronic sphygmomanometer; static pressur; uncertainty evaluation
目前,用于醫(yī)療衛(wèi)生的電子血壓計(jì)已經(jīng)被列入《實(shí)施強(qiáng)制管理的計(jì)量器具目錄》中。(剩余3835字)