特黄三级爱爱视频|国产1区2区强奸|舌L子伦熟妇aV|日韩美腿激情一区|6月丁香综合久久|一级毛片免费试看|在线黄色电影免费|国产主播自拍一区|99精品热爱视频|亚洲黄色先锋一区

膠接絕緣接頭常見傷損病害及整治方法

  • 打印
  • 收藏
收藏成功


打開文本圖片集

摘  要:絕緣接頭屬于工務(wù)和電務(wù)的結(jié)合部,是軌道電路的重要組成部分。文章對膠接絕緣接頭的作用及日常檢查作業(yè)標(biāo)準(zhǔn)進行論述,同時對其常見病害的產(chǎn)生原因、整治方法和絕緣接頭失效后的緊急處理進行總結(jié)歸納,以期為現(xiàn)場整治絕緣接頭病害提供借鑒。

關(guān)鍵詞:膠接絕緣接頭;膠接病害;整治方法;緊急處理

中圖分類號:U216.4      文獻標(biāo)志碼:A          文章編號:2095-2945(2022)20-0114-05

Abstract: Insulation joint is the joint of public works and electricity, and it is an important part of track circuit. This paper discusses the function and daily inspection operation standard of bonded insulation joint, and summarizes the causes of common diseases, treatment methods and emergency treatment after insulation joint failure, in order to provide reference for on-site treatment of insulation joint disease.

Keywords: cemented insulation joint; cementation disease; treatment method; emergency treatment

鋼軌絕緣接頭的作用是分割兩相鄰軌道中的信號電流,通過對信號電流的斷路和短路來控制鋼軌中的電流是否被接通,斷路時表示無車占用軌道,軌道空閑,可以接發(fā)列車;短路時表示有車占用軌道,車間軌道監(jiān)控系統(tǒng)產(chǎn)生紅光帶,無法接發(fā)列車,通?,F(xiàn)場以信號燈顯示紅燈,這是鐵路信號指揮系統(tǒng)的基礎(chǔ)設(shè)備。(剩余5399字)

目錄
monitor