600MW火電機組汽輪機回熱加熱器泄漏原因分析及解決措施

打開文本圖片集
中圖分類號:TM621 文獻標志碼:A 文章編號:1003-5168(2025)13-0029-04
DOI:10.19968/j.cnki.hnkj.1003-5168.2025.13.005
Analysis and Solution for Leakage in Regenerative Heaters of 6oo MW Thermal PowerUnitTurbines
ZHANG Xingkai (ShanxiDeyuan Fugu EnergyCo.,Ltd.,Yulin7194O7,China)
Abstract: [Purposes] To analyze leakage issues in 6OO MW thermal power unit regenerative heaters and explore effective solutions.[Methods] Field investigations and case studies were conducted to systematically summarize leakage causes in regenerative heaters.Actual operational data from a power plant were analyzed to investigate leakage mechanisms and verify preventive measures.[Findings] Four main leakage factors were identified: internal corrosion,mechanical damage,operational fluctuations,and improper maintenance. Corresponding systematic solutions were proposed,including water quality optimization control, mechanical damage prevention, operating parameter optimization, and preventive maintenance.[Conclusions] Comprehensive prevention and control measures can effctively reduce leakage risks,ensuring stable equipment operation and long-term reliable power supply for the power unit. Keywords: thermal power unit; regenerative heater; leakage causes
0 引言
火力發(fā)電在我國能源供給中占據(jù)重要地位。(剩余6368字)